| Terminal thickness: 6.2 | ||||
| Rigid conductor | Flexible conductor | I | Ui | |
| (mm2) | (A) | (V) | ||
| Connection data | 0.5-4 | 0.5-2.5 | 26 | 250* |
| * Voltage subject to the light emitting diode | ||||
Description | Color | Type |
Terminal: It can be mounted on the guide rail . | Grey | |
Blue | ||
Terminal: Same as above, but there is a red (RD) or green (GN) light emitting diode (LED) between the upper and middle layers. | 15-30 DC | |
15-30 DC | ||
Terminal: Same as above, but there is a red (RD) or green (GN) light emitting diode (LED) between the upper and lower layers. | 15-30 DC | JWD1-2.5B/3CG-LED24 RD/U-0 |
15-30 DC | JWD1-2.5B/3CG-LED24 GN/U-0 | |
(1) End plate | JWD1-2.5B/3CG-G | |
(2) Central liaison part: It is used in the middle of the terminal for horizontal bridging; screw head with 10 insulating rings which can be divided; with 10 screws | ZL6/10 | Imax: 26A |
(3) Edge liaison part: Used for bridging between the middle and lower layers of the terminal; separable tooth back insulation | BL 6/2 | |
BL 6/3 | ||
BL 6/10 | ||
(4) Divider It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space. | GP-1 | |
(4) Quick tag: 10 digits; white | ZP6 | |
Terminal dimensions | ||
Thickness / width / end plate thickness | [mm] | 6.2 / 62.5 |
Height (TH 35:7.5 / TH 35:15 / G 32:15) | [mm] | 67.2/75 |
Technical data based on IEC/DIN VDE standards | ||
Maximum rated working current / cross-sectional area | [A] / [mm2] | 26/4 |
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used: | [mm2] | 6/4 |
Rated impulse withstand voltage / degree of pollution | [kV]/- | 4.0 / 3.0 |
Over-voltage category / insulation material group | -/- | lll/l |
Connection capacity | ||
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal | [mm2] | 0.25-2.5/0.25-2.5 |
Connection of multiple conductors (two conductors with the same cross-sectional area) | ||
Rigid conductor / flexible conductor | [mm2] | 0.2-1 / 0.2-1 |
Flexible conductor with tubular bare terminal | [mm2] | 0.25-1 |
Flexible conductor with DEV-tubular pre-insulated terminal | [mm2] | 0.5-1 |
Stripping length | [mm] | 8 |
Screw type | M3 | |
Torque | [Nm] | 0.6-0.8 |
Insulation material type | PA | |
Material flammability according to UL94 | V0 | |
Certification data (UL and CAS) | ||
Rated working voltage / rated working current / wire gauge | U: [V]/[A]/AWG | 300/15/30-14 |