| Terminal thickness: 8.2 | ||||
| Solid conductor | Stranded conductor | I | Ui | |
| (mm2) | (A) | (V) | ||
| 0.5-10 | 0.5-6 | 57 | 400 | |
| IEC 60947-7-1 | ||||
| Description | Schematic diagram | Type | ||
| Test terminal: | JWD1-6S | |||
| With general-purpose locating base, suitable for standard mounting rails | ||||
| and | ||||
| Switching terminal: | ||||
| With general-purpose locating base, suitable for standard mounting rails | ||||
| and | ||||
| (1) End plate: | 6S G | |||
| One additional piece must be attached to the end of each terminal strip set. If it is mounted in the center of the terminal strip, the creepage distance may increase. | ||||
| (2) Central liaison part: | ZL 6S/10 | |||
| It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | ||||
| (3) Edge liaison part | 2 digits: | |||
| Its role is the same as that of the central liaison part (2); with insulation on the back side; 10 digits that can be further divided at will | ||||
| 3 digits: | ||||
| 10 digits: | ||||
| (4) Divider: | 6S GP (Thickness 0.8mm) | |||
| It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space. | ||||
| (5) Group partition: | 6S GF (Thickness 0.8mm) | |||
| Used for separation of each terminal group; with dual effects (visible grouping and electrical isolation) | ||||
| (6) Central liaison part | ||||
| It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will. | ||||
| (7) Switch liaison part | HL 6S/2-1 | |||
| It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed inwards to make it break; two screws are supplied. | ||||
| (8) Switch liaison part | HL 6S/2-2 | |||
| It can be used on both sides of the breaking sliding block for two terminals; the strap of the liaison part is pushed outwards to make it break; two screws are supplied. | ||||
| (9) Switch liaison part | HL 6S/2 | |||
| It is used for two terminals; please note that it can only be used on the right of terminals; two screws are supplied. | ||||
| (10) Switch liaison part | HL 6S/4 | |||
| It is used for the short circuit of a three-phase interconnected current transformer and can only be used on the right of the terminal; 1) four screws are supplied. | ||||
| (11) Test plug: | ZP8/10 | |||
| (12) Conversion test plug: | ||||
| (13) Tag: | ||||
Terminal dimensions | |||
Thickness / width / end plate thickness | [mm] | 8.2/72/2.2 | |
Height (TH 35:7.5 / TH 35:15 / G 32:15) | [mm] | 51.5/59/56 | |
Technical data based on IEC/DIN VDE standards | |||
Maximum rated working current / cross-sectional area | [A]/ [mm] | 57/10 | |
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used | [mm2] | - | |
Rated impulse withstand voltage / degree of pollution | [kV]/- | 6/3 | |
Over-voltage category / insulation material group | -/- | III/I | |
Connection capacity | |||
Flexible conductor with tubular bare terminal / tubular pre-insulated terminal | [mm2] | 0.5-6 / 0.5-4 | |
Connection of multiple conductors (connecting two conductors with the same cross-sectional area) | |||
Rigid conductor / flexible conductor | [mm2] | 0.5-2.5/0.5-6 | |
Flexible conductor with tubular bare terminal | [mm2] | 0.5-4 | |
Flexible conductor with DEV-tubular pre-insulated terminal | [mm2] | 0.5-4 | |
Stripping length | [mm] | 13 | |
Screw for terminal position: screw / torque | [Nm] | M4/1.5-1.8 | |
Screw for breaking sliding block: screw / torque | [Nm] | M3.5/1.0-1.3 | |
Insulation material type | PA | ||
Material flammability according to UL94 | V0 | ||
Rated working voltage / rated working current / wire gauge | UL:[V]/[A]/AWG | 300/50/26-8 | |
English