Email Us
JWD1-4/2LSJ Screw Type - Double Layers Connected Terminal Block with Din Rail

JWD1-4/2LSJ Screw Type - Double Layers Connected Terminal Block with Din Rail

1. Wiring gauge: 0.2-4mm².

2. Four wiring holes, connect together on both layer as shown.

3. Utilizes a screwdriver, featuring high clamping force and maintenance-free operation. This type of terminal block supports multi-wire connections at a single connection point, allowing for wire connection without pretreatment.

4. Enables multi-digit shorting or bridging.

5. Markers meet the marking needs of users in different scenarios.

6. Can be used in areas with explosive atmospheres (according to IEC/EN 60079 EX eb IIC Gb G D).

  • Product Description
  • Parameters
  • Certification
Terminal thickness: 6.2mm

Rigid wire
Flexible wireIUi

(mm2)(A)(V)
IEC 60947-7-10.2-40.2-432*500
* The total current of all the connected conductors should not exceed the maximum rated working current of the terminal block.


DescriptionColorSchematic diagramType
Terminal:Grey

With general-purpose locating base, suitable for standard mounting rails
and


Blue

Top and bottom interconnected terminals:Grey
JWD1-4/2LSJ
The mounting and use methods are the same as above; the conducting plates in the upper and lower layers are interconnected to achieve the same potential of top and bottom connecting points.

Blue
JWD1-4/2LSJ BU
(1) End plate: (thickness: 2.5)Grey
2.5-4/2 LG
One additional piece must be attached to the end of each terminal strip set. If it is mounted in the center of the terminal strip, the creepage distance may increase.

Blue
2.5-4/2 LG BU
(2) Compensating end plate: (thickness: 2.5)Grey
2.5-4/2LBD
It is used to offset interlayer displacement while it is adjacent to an ordinary terminal.

Blue
2.5-4/2LBD BU
(3) Compensating end plate: (thickness: 2.5)
2.5-4/2 LBD-1
It is used for terminal locating and fastening of the terminal strip or for offsetting interlayer displacement while it is arranged with other terminals in the same group.
(4) Central liaison part:
ZL6/10
It is used to connect terminals with the same specification and form a liaison terminal group; each part has 10 digits (supplied with screws) that can be further divided at will.
(5) Connecting sheet:
LJ 6/2
For central connection of more than 10 digits
(6) Edge liaison part:2 digits:
BL6/2
Its role is the same as that of the central liaison part (4); with insulation on the back side; 10 digits that can be further divided at will

3 digits:
BL6/3

10 digits:
BL6/10
(7) Jumping liaison part:
KL6/10
With the spacer (8), it can connect any non-adjacent terminals in the center to form a jumping liaison terminal group.
(8) Spacer:
K6
Used as a spacer block between the accessory of the jumping liaison part (7) and the conductive part of the terminal
(9) Divider:
GP-1
It is used to separate two adjacent liaison terminal groups and can be inserted after assembly, without any effect on the overall space.
(10) Group partition: (thickness: 2.5)
2.5-4/2 GF
Used for separation of each terminal group; with dual effects (visible grouping and electrical isolation)
(11) Tag:
ZP6


Terminal dimensions

Thickness / width / end plate thickness[mm]6.2/67/2.5
Height (TH 35:7.5 / TH 35:15 / G 32:15)[mm]62/69.5/67
Technical data based on IEC/DIN VDE standards

Maximum rated working current / cross-sectional area[A] / [mm2]Apr-32
Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used:[mm2]4/2.5
Rated impulse withstand voltage / degree of pollution[kV]/-6/3
Over-voltage category / insulation material group-/-lll/l
Connection capacity

Flexible conductor with tubular bare terminal / tubular pre-insulated terminal[mm2]0.25^ / 0.25-2.5
Connection of multiple conductors (two conductors with the same cross-sectional area)

Rigid conductor / flexible conductor[mm2]0.2-1.5 / 0.2-1.5
Flexible conductor with tubular bare terminal[mm2]0.25-1.5
Flexible conductor with DEV-tubular pre-insulated terminal[mm2]0.5-1.5
Stripping length[mm]8
Screw type
M3
Torque[Nm]0.6-0.8
Insulation material type
PA
Material flammability according to UL94
V0
Rated working voltage / rated working current / wire gaugeUL:[V]/[A]/AWG500/30/26-12
Note: When an edge liaison part is used, a cable below 1.5 mm2 should be used for a 2.5 mm2 terminal; corresponding cables should be used for terminals with other cross-sectional areas (mm2).


ce
eac
rohs
ul with r certificate