Email Us
JWD2-1.5a/1-2 Spring-Cage Din-Rail TB

JWD2-1.5a/1-2 Spring-Cage Din-Rail TB

For power distribution, the application of the three-conductor spring terminal JWD2.../1-2 can greatly save the space and costs.

Actually, one terminal is usually required to connect three conductors. The terminal (/1-2) can connect three conductors without any additional terminals or bridgeware.

The connection mode of the general-purpose FBS plug-in bridgeware can achieve horizontal connection of adjacent straight-way terminals.

  • Product Description
  • Parameters
  • Certification

Rigid solidFlexible multi-conductorIUi

(mm2)(A)(V)
IEC 60947-7-10.14-1.50.14-1.517.5*500
* The total current of all connections should not exceed the maximum load current.


Terminal dimensions

Thickness / length / end plate thickness[mm]16/100/-
Height (TH 35:7.5 / TH 35:15)[mm]59/66.5
Technical data in accordance with IEC/DIN VDE standards

Maximum rated working current / cross-sectional area[A] / [mm2]115/35
Rated impulse withstand voltage / degree of pollution[KV] / -8/3
Over-voltage category / insulation material group- / -III/I
Connection

Flexible wire with ferrule[mm2]2.5-35
Flexible wire with cable lug[mm2]2.5-35



Stripping length[mm]25
Plug gauge (IEC60947-1)
A8
Insulation material
PA
Grading as per UL 94
V0
Certification data (UL and CSA/CUL)

Rated working voltage / rated working current / wire gaugeUL: [V]/[A]/AWG-
CSA/CUL: [V]/[A]/AWG-

Terminal dimensions



Thickness / length /end plate thickness

[mm]

4.2/60.5/2.2

Height (TH 35:7.5 / TH 35:15)

[mm]

36.5/44

Technical data in accordance with IEC/DIN VDE standards



Maximum rated working current / cross-sectional area

[A] / [mm2]

17.5/1.5

Rated impulse withstand voltage / degree of pollution

[KV] / -

6/3

Over-voltage category / insulation material group

- / -

lll/l

Connection



Flexible wire with ferrule

[mm2]

0.25-1.5

Flexible wire with cable lug

[mm2]

0.25-1.5




Stripping length

[mm]

10

Plug gauge (IEC60947-1)


A1

Insulation material


PA

Grading as per UL 94


V0

Certification data (UL and CSA/CUL)



Rated working voltage / rated working current / wire gauge

UL: [V]/[A]/AWG

CSA/CUL: [V]/[A]/AWG

-


ce
eac
rohs
ul with r certificate