| Terminal thickness: 31 | ||||
| Rigid conductor | Flexible conductor | I | Ui | |
| (mm2) | (A) | (V) | ||
| IEC 60947-7-1 | 35-150 | 50-150 | 309 | 1000 |
Products Category
JWD1-150 Screw Type High-Current Din-Rail TB
Product Description
Parameters
Certification
| Description | Color | Type |
| Terminal: With general-purpose locating base, suitable for standard mounting rails |
Grey | JWD1-150 |
| Blue | JWD1-150 BU | |
| Yellow-green | ||
| (1) Central liaison part: It is used to connect terminals with the same specification and form a liaison terminal group; the divider on the terminal housing must be removed. |
2 digits | |
| 3 digits | ||
| (2) Edge liaison part: Its role is the same as that of the central liaison part (1); with insulation on the back side, inserted in the conductor holder, and clamped on the insulation housing of the terminal |
2 digits | BL 31/2 |
| 3 digits | BL 31/3 | |
| (3) Prismatic conductor holder: A prismatic metal block used to compensate the pressed flat conductor |
150 | |
| (4) Warning sign: Attached to the surface on top of the terminal |
||
| (5) Tag: It can be quickly inserted in the upper grooves on both sides of the terminal as a whole for any identification. It has a total of 10 digits (to be divided at will). |
ZP10 | |
| (6) Terminal fastener: (thickness: 10) It is used to finally fix a large-current terminal; after it is pushed, it can be mounted on Type TH35/15 mounting rail, and it should be fixed with two screws. |
ZG2 |
| Terminal dimensions | ||
| Thickness / width / end plate thickness | [mm] | 31/100 |
| Height (TH 35:7.5 / TH 35:15 / G 32:15) | [mm] | 118.5/116 |
| Technical data based on IEC/DIN VDE standards | ||
| Maximum rated working current / cross-sectional area | [A] / [mm2] | 309/150 |
| Maximum cross-sectional area of conductors (rigid / flexible) that can be connected if any edge liaison part is used: | [mm2] | 150/120 |
| Rated impulse withstand voltage / degree of pollution | [kV]/- | 45507 |
| Over-voltage category / insulation material group | -/- | III/I |
| Connection capacity | ||
| Flexible conductor with tubular bare terminal / tubular pre-insulated terminal | [mm2] | 50-150/50-150 |
| Connection of multiple conductors (two conductors with the same cross-sectional area) | ||
| Rigid conductor / flexible conductor | [mm2] | 25-50/35-50 |
| Flexible conductor with tubular bare terminal | [mm2] | 25-50 |
| Stripping length | [mm] | 40 |
| Screw type | M10* | |
| Torque | [Nm] | 25-30 |
| Insulation material type | PA | |
| Material flammability according to UL94 | V0 | |
| Rated working voltage / rated working current / wire gauge | UL: [V]/[A]/AWG | 600/285/2AWG-300MCM |
| • Good dielectric property and arc resistance: outstanding withstand voltage strength (600 KV/cm); creepage: CTI>600; |
| • Excellent corrosion and weather resistance, as well as good protection from microorganisms and moulds in nature, various compounds, etc.; |
Welcome to consult us for more information!